I.C.P
Composition analysis
S.R.R Analysis
S.R.R Analysis
¡@
Optical Measurement
Solder ball size
Oxygen analyzer
Oxygen Test
¡@
¡@
¡@
¡@
¡@
¡@
Leakage Test
Burst Test
Life Test
Accelerate Life Test
Thermal Cycle Test
Thermal Shock Test
 
Test Instrument: Oven
Condition: 200 degree C, 1 hour.
Stage : New production pilot run & M/P
Test Criteria:
should pass ¡µ T Test 2days later repeat the Test . ¡µ T¡Ø5°C
 
Test Instrument: heater block
Condition: burst temp. over 220°C
Stage : New production pilot run & M/P
Test Criteria:
burst temp. should over 220°C
 
Test Instrument: Ambient
Condition: New production pilot run
Stage : New production pilot run & M/P
Test Criteria:
Should pass functional test Test
4.1 Within 1 year: Each month test
4.2 1 year later: 6 months test
4.3 3 year later:12 months test
Continued 5 years
 
Test Instrument: Oven
Condition: 180°C, 36 hours
Stage : New production pilot run
Test Criteria:
should pass functional
test after test ¡µ T 5°C
 
Test Instrument: Thermal Cycling chamber
Condition:
125°C~-40°C, dwell and
transition time, 60 Min, each cycle 4 hours
Stage : New production pilot run & M/P
Test Criteria:
should pass functional test
after 10 cycles ¡µ T °C
outer diameter ¡Ó3% .
 
Test Instrument:Thermal shock chamber
Condition:
125°C~-40°C, dwell time, 5
Min, , transition time 0.5 Min,
cycle time 10.5 Min
Stage : New production pilot run
Test Criteria:
should pass functional test
after 250 cycle Delta T 5°C
outer diameter ¡Ó3%
 
Burn-In Test
Helium burn Test
Performance Test
Q-max Test
 
Test Instrument: Oven
Stage : On line , 100%
Test Criteria:
Should pass functional test
 
Test Instrument:Helium chamber
Stage : On line , 100%
Test Criteria:
Should pass functional test
 
Test Instrument:thermograph tester
Stage : 100% an overall inspection
Test Criteria:
Should pass functional test
 
 
¡@
¡@
Copyright (C) YEH-CHIANG TECHNOLOGY CORP.